Online Mash UPS High Frequency EA900R

Application

Mash EA900R series, one phase UPS(1KVA-10KVA),High Density Double conversion online offer advanced PFC Technology control, True sine wave, 19”U Rack, and online power protection. Capable of supporting load up to 10KVA in Rack form. The EA900R Online is Available up to 19U. EA9010 is capable of supporting Blade Servers and over loaded rack equipment. Upon request UPS System can be configured with appropriate external Battery packs with extended Run time to meet several demands.

EA900R High frequency UPS usually used for Centralized server rooms and blade server centers, mainframe, network control center, cable structure racks, point-of sales, branch offices, computing center …etc.

Description

Features:

• 19′ Rack-mount
• High frequency and dual conversion on-line technology
• Advanced PFC technology
• True sine wave output with less than 3% THD
• Self-diagnosis when UPS startup
• Advanced battery management (ABM)
• Cold start feature (DC power on)
• Automatically charging batteries in UPS off mode
• Lightning and surge protections(surge energy rating 1050 Joules)
• Short circuit and overload protections
• Fan speed automatically changes as load varies
• Optional external battery pack
• EMI/RFI noise filter
• (SNMP Optional)
Shutdown & restart schedule

 

Technical specifications:

Model EA901R-1KVA EA902R-2KVA EA903R-3KVA EA906R-6KVA EA9010R-10KVA
Capacity(linear Load) 1KVA/700W 2KVA/1400W 3KVA/2100W 6KVA/4200W 10KVA/7KW
Input Voltage Range Half Load 120-300VAC

Full Load 165V-276VAC

176V-290VAC
Frequency Range 45.5Hz~54Hz
Output Voltage 220/230/240V±1%
Output Frequency 50/60Hz±0.5Hz
Output Voltage Tolerance <±5%(100% Load or without Load)
Distortion <3%(Linear Load);  <5%(Non-linear load)
Output Waveform True Sine Wave
Overload Capability 110%~150%: transfer to Bypass after

1Mins, above 150%: 200MS

105%~130%, 10Mins; >130%:1Min.
Battery Voltage 36VDC 96VDC 240VDC
Charge Voltage 40.5±1V 110±1V 274.5±1V
Charge Current Standard model 1A ,

Long back model 7.5A ;

Standard model 1.5A ;

Long back model 4.5A

Battery Type Sealed Maintenance-FreeLead-Acid
Batteries Q’TY 12V×3Pcs 12V×8Pcs 12V×20Pcs
Standard Backup Time(Full Load/Half Load) 5/12Mins 7/16Mins 5/13Mins 6/15Mins 8/20Mins
Crest Factor 3:1
Noise( 1m ) <45db <50db <55db
LCD and LED Utility, Inverter, Bypass, Battery, Load, Battery Mode, Frequency,

UPS Fault Indicator

Transfer Time of AC to DC Zero
Battery Low Voltage 31±2V 83±2V 200±2V 210±2V
Charge Time Charging up to 90% , ≤8Hours
Audible Alarm-Battery Discharge Utility Failure, Beep/4s ; Battery Low, Beep/1s
EMC 50091 , 9254
UPS Abnormal Continuous Beep and Red LED on
Output Short Circuit Shutdown
Outlets 2pcs 3pcs Terminals
Communication Interface RS232/SNMP (optional)
Ambient Temperature 0 ℃ ~ 40 ℃
Humidity 10%~90%
Net Weight(Kg) 6.5(H)./12.3(S) 13.2(H)./28(S) 13.2(H)./28(S) 40.5(H)./87(S)
Dimension(W×D×H)mm 145×415×215 190×470×330 260×730×560
Packing Measure (W×D×H)mm 236×492×316 337×602×482 337×602×482