MASH Online UPS MA900IIT

Online UPS 10Kva-60Kva scalable to 6 units.

Mash MA900IIT State-of-the-art three phase power protection designed to meet a wide range of requirements from medium data centers to industrial and facilities applications, it can grow as your business grows, scalable up to 6 units Parallel/ redundant.

MA900IIT (3/3) series UPS is an advanced three-phase-on line high frequency UPS with full digital control technology, supporting three phase in single phase out working mode as well. It breaks the traditional design of tower UPS, adopting the idea of advanced modular design. This series not only ensures the compactness of layout but also enhances the system’s reliability. With its excellent electrical properties and perfect protective function in soft and hardware. MA900IIT (3/3) series UPS could adapt to different Utility Powers and provide safe and reliable power protection for different loads

Category:

datasheet

Description

Features

  • Full digitized DSP control technology
  • True on-line double conversion with strong load-taking capability
  • Support three phase in single phase out working mode
  • Input power factor up to 0.99 lower harmonic current green power, high efficiency & energy saving
  • Wide input voltage range, 50Hz/60Hz frequency self-adaptable, adapt to different utility condition
  • Support two modes of frequency conversion: 50Hz input/60Hz output and 60Hz input/50Hz output, satisfy user’s special requirement.
  • N+X redundancy parallel up to 6 unit
  • Share battery pack in Parallel operation, saving user’s battery cost.
  • Digitized charger, with flexible charging parameter setting and battery configuration
  • Advanced intelligent battery management technique, prolong the working life of battery effectively.
  • Support battery could start and mains supply self-starting, satisfy the user’s requirement
  • Complete Isolation Design between fragile components and air flow, improving the system reliability greatly.
  • Easy to maintained.
  • Perfect protective function in soft hardware, robust, self-diagnose, abundant event log for future check
  • 5.7 inches multifunctional LCD touch screen, friendly human & machine interface.
  • Abundant communication port, including RS232, RS485, USB and SNMP … etc.

 

Technical specifications:

Model MA9010IIT MA9015IIT MA9020IIT MA9030IIT MA9040IIT MA9060IIT
Nominal capacity 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA
Input
Rated input voltage 380Vac
Load ≤ 50% 204~520Vac
50%< load ≤70% 242~520Vac
70%< load ≤100% 304~520Vac
Input mode Three-phase five-wire system
Input power factor ≥0.99
Total harmonic distortion (THDi) ≤3%
Rated frequency 50Hz/60Hz Auto- Sensing
AC main power input 40~70Hz
Bypass voltage range 380Vac *(1±20%) stablized
Output
Output power factor 0.9
Rated voltage 400V 3PH , Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Voltage precision ±1%
Dynamic voltage transient range ±5% (0-100% load fluctuation)
Total harmonic distortion (THDV) ≤1 % (resistive load);
≤3% (nonlinear load)
Output voltage direct current component ≤100mv
Output current peak factor 3:01
Output frequency Main power mode: synchronous with main power; battery mode: 50Hz/60Hz
Battery mode 50 Hz/60Hz
Frequency tracking rate ≤1 Hz/s
Phase lock accuracy 1°
Inverter overload capability 100%<load≤125%, switch to bypass after 10 minutes;
125%<load≤150%, switch to bypass after 1 minute;
Load>150%, switch to bypass after 0.5s
Bypass overload capability ≤150%, operate for long time; >150%, continue for 10s
Transfer from main to Battery mode 0 ms
Transfer from Battery Mode to Main 0 ms
System
Working efficiency of unit ≥93% (≥50% load)
Battery configuration ±192V~±240V (positive/negative battery group with 16, 17, 18, 19 and 20 pieces for each group for option, 32 pieces 12V/7AH or 12V/9AH are equipped for standard machine, the battery space can allow 64 pieces batteries for Extra backup time use external Battery racks
Charging  current 12A 24A
Parallel/ Redundant up to 6 Units
Parallel-capacity capable Increases total power capacity by using multiple UPSs simultaneously
Parallel-redundant capable Power the connected equipment multiple UPSs to increase system redundancy
Working temperature range 0~40℃
Output Connections (1) Hard Wire 4-wire (3PH + G)  Or (1) Hard Wire 5-wire (3PH + N + G)
Manageability (optional ) Customize UPS capabilities with management cards, Provides remote management of the UPS over the network.
Storage temperature -25 ~ 55℃
Noise in 1m from ground <60dB
Safety EN62040-1-1
Electrostatic discharge IEC 61000-4-2  Level 3
Sustained electromagnetic sensitivity IEC 61000-4-3  Level 3
Voltage flash compatibility IEC 61000-4-4  Level 3
Surge interference IEC 61000-4-5  Level 4
Electromagnetic interference EN62040-2 (>25A) class A
UPS cabinet size 600mm*800mm*1280mm
Weight (kg) 158 164 164 174 190
Color Black
Control panel 5.7 inch multifunctional LCD touch wide screen
Audible alarm Alarm of battery mode; when voltage of battery is too low; alarm of fan fault, etc.
Port USB, RS232, RS485 and dry contact (standard equipped)
Optional SNMP card, Parallel units device
Warranty 2 Years
Mengapa Mitologi Yunani Selalu Laku Jadi Tema Game? Ini Rahasianya Bukan Cuma Petir, Ini Arti Simbol Mahkota dan Cawan di Game Olympus Mengenal Fitur Pengali Gambar Emas Di Mahjong Ways dan Cara Kerjanya Mengenal Demam 'Magical Girl', Genre Jepang yang Bikin Starlight Princess Viral Mengapa Mahjong Ways 2 Lebih Populer Dibanding Versi Pertamanya? Ini Alasannya Cara Membaca Pola Simbol Naga di Mahjong Ways untuk Pemula Agar Cuan Setiap Hari Trik Mengatur Ritme Taruhan Di Mahjong Ways Demi Menjaga Saldo Tetap Aman Kisah di Balik Gates of Olympus: Alasan Zeus Jadi Tokoh Utama Alasan Mengapa Desain Ala Anime Jepang Begitu Melekat di Starlight Princess Analisis Volatilitas Mahjong Ways: Kapan Waktu Terbaik untuk Berhenti? Cara Membaca Pola Simbol Naga di Mahjong Ways untuk Pemula Agar Cuan Setiap Hari Trik Mengatur Ritme Taruhan Di Mahjong Ways Demi Menjaga Saldo Tetap Aman Kisah di Balik Gates of Olympus: Alasan Zeus Jadi Tokoh Utama Alasan Mengapa Desain Ala Anime Jepang Begitu Melekat di Starlight Princess Analisis Volatilitas Mahjong Ways: Kapan Waktu Terbaik untuk Berhenti? Bukan Cuma Visual, Musik Starlight Princess Ternyata Terinspirasi Game Arked Jepang2 Arti di Balik Simbol Bulan dan Bintang dalam Game Starlight Princess Mengintip Keindahan Kastil di Atas Awan, Latar Magis Starlight Princess Mengapa Karakter Starlight Princess Punya Sayap? Ini Kisah Fantasi di Baliknya Kontras dari Zeus! Mengapa Starlight Princess Ambil Tema Feminin dan Anime?Dewa Yunani Lahir di Era Dinasti Qing, Ini Sejarah Permainan Tradisional di Balik Mahjong Ways Arti Aksara 'Fa Cai' di Mahjong Ways: Simbol Kemakmuran Warga Tionghoa Banyak yang Belum Tahu, Ternyata Ini Arti Aksara Naga Hijau di Mahjong Ways! Bukan Sekadar Gambar, Simbol di Mahjong Ways Ini Ternyata Punya Arti Mengejutkan Mengejutkan, Game Populer Mahjong Ways Ternyata Lahir dari Tradisi Dinasti Qing!