Description
Specifications:
MODEL | MASKN-SC 1KW/12 | MASKN-SC 2KW/24 | MASKN-SC 3KW/24 | MASKN-SC 4KW/48 | MASKN-SC 5KW/48 | MASKN-SC 6KW/48 | |
SPECIFICATION | |||||||
DC INPUT | |||||||
Input Voltage(Vdc) | 12V/24V | 24V | |||||
Min DC start voltage(Vdc) | 10V/20V | 20V | |||||
AC Bypass | |||||||
Nominal Input Voltage | 110V or 230Vac (waveform: Sine or generator) | 230Vac(waveform: Sine or generator) | |||||
Input AC Range(Vac) | 90Vac±4%-135Vac±4% or 184Vac±4%-253Vac±4% | 184Vac±4%-253Vac±4% | |||||
Frequency Range(HZ) | 57Hz or 60Hz(47Hz -53Hz for 50Hz)—–{57Hz -63Hz for 60Hz} | ||||||
Input Frequency(Hz) | 50Hz/ 60Hz (Auto detection) | ||||||
Bypass Output Voltage(Vac) | same as input voltage | ||||||
Bypass Output Frequency(Hz) | same as input frequency | ||||||
Pass through without Battery | Yes | ||||||
Max Bypass Overload Current | 10A | 30A | 40A | ||||
AC Efficiency | > 95% | ||||||
Transfer Time(ms) | 20ms (typical) | ||||||
Solar controller | |||||||
Solar controller | 50A/12V OR 24V | 50A/12V OR 24V | 50A/12V OR 24V | 50A/ 24V | 50A/ 24V | 50A/ 24V | |
AC CHARGER | |||||||
Charge mode Input Voltage Range | 95~127Vac or 196~243Vac | 196~243Vac | |||||
Automatic Charge mode | Three stage charge mode: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | ||||||
Nominal Charge Voltage | According to the battery type setup | ||||||
Charge Current(A) | 17.5A/35A/70A | ||||||
Charge boost voltage(v) | According to the battery type setup( 12V BAT:14-15.5v 24V BAT: 28-31V 48V BAT:56-62V 96V BAT:112-124V) | ||||||
Charge Floating Voltage(V) | According to the battery type setup (12V BAT: 13.3-13.7, 24v BAT: 26.6-27.6, 48V BAT:53.2-55.2V 96V BAT:106.4-110.4V) | ||||||
Over Charge Protection | Bat. V ≥15.7Vdc, beeps 0.5s every 1s & fault after 60s (15.7 for 12v, 31.4V for 24V, 62.8V for 48V, 125.6V for 96V) | ||||||
Charger Short Circuit Protection | Circuit breaker | ||||||
(INVERTER) | |||||||
Capacity(VA) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | |
Output Power(W) | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | |
Power Factor(PF) | 1 | ||||||
Output Voltage | 120VAC or 230VAC (Sine wave) | 230VAC (Sine wave) | |||||
Output Frequency | 50/60 ± 0.3Hz(auto tracking main first power connection) | ||||||
Wave | pure sine wave | ||||||
Inversion Efficiency | >88% | ||||||
Over load capacity | (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes; (125%<load<150%) ±10%: Fault (shutdown output) after 60s; Load>150% ±10%: Fault (shutdown output) after 20s |
||||||
Low Battery Alarm | 10.5Vdc ± 0.3Vdc for 12V battery, 21.0Vdc ± 0.6Vdc for 24V battery, 42.0Vdc ± 1.2Vdc for 48V battery, 84.0Vdc ± 2.4Vdc for 96V battery | ||||||
Power saver | Load ≦25W (Enabled on “P/S auto” setting of Remote control) | ||||||
AMBIENT | |||||||
Noise(dB) | 60dB max. | ||||||
Temperature | 0°C to 40°C | ||||||
Humidity | 5% to 95% | ||||||
Sea Level(m) | ≤1500 | ||||||
DIMENSION | |||||||
Packing size | L630mm*W392mm*H295mm | L870mm*W392mm*H295mm | |||||
Warranty | 2 years Manufacturing Warranty |