Mash MASKN-SC Series Low Frequency Off-Grid Solar Generator

Main Features

• Extremely low return noise, no disturbance to talking quality.
• Use-friendly interface, LED simulative display and computer screen display of inverter operation status.
• RS232 port, smart power management software, automatic file saving and shutting down at power abnormalities.
• Special charging system design for better protection of battery life.
• Short circuit, overload, over voltage and low battery protection.
• Compatible with generators and suitable for harsh environment where power voltage is extremely unstable.

 

Overview:

Sine Wave Inverter/Charger System
The Desirable Long Backup Power Solution for Home and Office Appliances

Description

Specifications:

MODEL MASKN-SC 1KW/12 MASKN-SC 2KW/24 MASKN-SC 3KW/24 MASKN-SC 4KW/48 MASKN-SC 5KW/48 MASKN-SC 6KW/48
SPECIFICATION
DC INPUT
Input Voltage(Vdc) 12V/24V 24V
Min DC start voltage(Vdc) 10V/20V 20V
AC Bypass
Nominal Input Voltage 110V or 230Vac (waveform: Sine or generator) 230Vac(waveform: Sine or generator)
Input AC Range(Vac) 90Vac±4%-135Vac±4% or 184Vac±4%-253Vac±4% 184Vac±4%-253Vac±4%
Frequency Range(HZ) 57Hz or 60Hz(47Hz -53Hz for 50Hz)—–{57Hz -63Hz for 60Hz}
Input Frequency(Hz) 50Hz/ 60Hz  (Auto detection)
Bypass Output Voltage(Vac) same as input voltage
Bypass Output Frequency(Hz) same as input frequency
Pass through without Battery Yes
Max Bypass Overload Current 10A 30A 40A
AC  Efficiency > 95%
Transfer Time(ms) 20ms (typical)
Solar controller
Solar controller 50A/12V OR 24V 50A/12V OR 24V 50A/12V OR 24V 50A/ 24V 50A/ 24V 50A/ 24V
AC CHARGER
Charge mode Input Voltage Range 95~127Vac or 196~243Vac 196~243Vac
Automatic Charge mode Three stage charge mode: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage)
Nominal Charge Voltage According to the battery type setup
Charge Current(A) 17.5A/35A/70A
Charge boost voltage(v) According to the battery type setup( 12V BAT:14-15.5v   24V BAT:   28-31V   48V BAT:56-62V  96V BAT:112-124V)
Charge Floating Voltage(V) According to the battery type setup (12V BAT: 13.3-13.7,  24v BAT: 26.6-27.6,  48V BAT:53.2-55.2V 96V BAT:106.4-110.4V)
Over Charge Protection Bat. V ≥15.7Vdc, beeps 0.5s every 1s & fault after 60s (15.7 for 12v,  31.4V for 24V,  62.8V for 48V,  125.6V for 96V)
Charger Short Circuit Protection Circuit breaker
(INVERTER)
Capacity(VA) 1000 2000 3000 4000 5000 6000
Output Power(W) 1000 2000 3000 4000 5000 6000
Power Factor(PF) 1
Output Voltage 120VAC or 230VAC  (Sine wave) 230VAC  (Sine wave)
Output Frequency 50/60 ± 0.3Hz(auto tracking main first power connection)
Wave pure sine wave
Inversion Efficiency >88%
Over load capacity (110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes;
(125%<load<150%) ±10%: Fault (shutdown output) after 60s;
Load>150% ±10%:  Fault (shutdown output) after 20s
Low Battery Alarm 10.5Vdc ± 0.3Vdc for 12V battery,  21.0Vdc ± 0.6Vdc for 24V battery,  42.0Vdc ± 1.2Vdc for 48V battery, 84.0Vdc ± 2.4Vdc for 96V battery
Power saver Load ≦25W (Enabled on “P/S auto” setting of Remote control)
AMBIENT
Noise(dB) 60dB max.
Temperature 0°C to 40°C
Humidity 5% to 95%
Sea Level(m) ≤1500
DIMENSION
Packing size L630mm*W392mm*H295mm L870mm*W392mm*H295mm
Warranty 2 years Manufacturing Warranty